Technical Specifications
| Measuring Gas | Carbon Monoxide (CO) |
| Measuring Range | 0 ppm to 1000 ppm |
| Extreme Overload | 2000 ppm |
| Output Signal | 1.5 to 3.5 nA per ppm |
| Repetitiveness | ±2% |
| Resolution Ratio | 0.5 ppm |
| Working Pressure Range | 14.5 psi ± 1.45 psi (0.1 MPa ± 10%) |
| Recommended Load Resistance | 1 kΩ |
| Typical Response Time (t90) | <60 Seconds |
| Long-Term Output Drift | <2 % per month |
| Working Temperature | -4 °F to +131 °F (-20 °C to +55 °C) |
| Working Humidity | 15 % to 90 % RH |









Reviews